Site Address:
|
827 S PACIFIC ST OCEANSIDE, CA 92054
|
Site APN:
|
1503561700
|
Subdivision:
|
MYERS ANNEX
|
Site Block:
|
|
Site Lot:
|
|
Valuation:
|
$1,340,000.00
|
Site Tract:
|
|
Permit Status:
|
FINALED
|
|
Description of Work:
|
BUILD NEW 2 CONDOMINIUMS ON VACANT LOT IN 3-STORIES OVER BAS
|
|
|
Contractor:
|
|
Address:
|
|
Phone:
|
|
|
Technical Information:
|
PLAN ID # | |
PERMIT # | |
BIN # | O-7 |
SPRINKLER | |
REDEV AREA | |
HOT WATER CONSERVATION | |
FLOOD ZONE | X, 0.2 |
COASTAL ZONE | |
OCC GROUP | R3 |
TYPE CONST | VB |
USE CODE | 021 |
EXISTING BLDG SF | |
OCC LOAD | 34 |
UNITS | 0 |
STATE CODE EDITION | 2016 |
BLDG SF | 6731 |
NO STORIES | 0 |
ELECTRIC RELEASED BY | |
NOTIFIED SDGE BY | |
DATE ELECTRIC RELEASED | 12:00:00 AM |
ELECTRIC RELEASE TYPE | |
TYPE OF BUILDING | |
GAS RELEASED BY | |
NOTIFIED SDGE BY | |
DATE GAS RELEASED | 12:00:00 AM |
GAS RELEASE TYPE | |
WDID # | |
|
|
|
Owner:
|
SUNSET VIEW L L C
|
Address:
|
3425 OCEAN BLVD CORONA DL MAR CA 92625
|
Phone:
|
|
|
|
|
WORKERS COMPENSATION DECLARATION
|
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
I hereby affirm under penalty of perjury one of the following declarations:
____ I have and will maintain a certificate of consent to self-insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
Policy No.
____ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number: Expiration Date:
____ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
|
LICENSED CONTRACTOR'S DECLARATION
|
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.
License No:
Expiration Date:
Contractor:
Class:
|
|
|
Inspections:
|
60 SETBACKS | PASS | 3/11/2020 | BING COSBY |
110 FOOTINGS | PASS | 3/20/2020 | BING COSBY |
495 PLB UNDERGROUND | PASS | 2/13/2020 | DAVID GANS |
305 FRAME (W/M,P&E) | | | |
605 INSULATION | PASS | 6/18/2020 | BING COSBY |
705 WALL BOARD | PASS | 6/22/2020 | BING COSBY |
730 LATH | PASS | 6/22/2020 | BING COSBY |
485 GAS TEST | | | |
550 METER RELEASE | PASS | 6/9/2020 | BING COSBY |
991 LANDSCAPING | | | |
992 STREET LIGHTING | NO INSPECTION | 8/17/2020 | KEITH PIRILLO |
993 ENGINEERING | PASS | 8/17/2020 | KEITH PIRILLO |
996 WATER UTILITIES | | | |
997 PLANNING | | | |
**905 FINAL SFR | | | |
900 FIRE FINAL | | | |
705 WALL BOARD | | | |
730 LATH | | | |
**905 FINAL SFR | FAILED | 3/26/2020 | BING COSBY |
110 FOOTINGS | PASS | 3/11/2020 | BING COSBY |
321 DIAPRAGM FLOOR | PASS | 4/14/2020 | BING COSBY |
321 DIAPRAGM FLOOR | PASS | 4/15/2020 | BING COSBY |
340 SHEAR & DIAPRAGM | PASS | 4/22/2020 | BING COSBY |
321 DIAPRAGM FLOOR | PASS | 4/27/2020 | BING COSBY |
321 DIAPRAGM FLOOR | PASS | 4/28/2020 | BING COSBY |
322 DIAPRAGM SHEAR | PASS | 5/7/2020 | BING COSBY |
321 DIAPRAGM FLOOR | PASS | 5/12/2020 | BING COSBY |
322 DIAPRAGM SHEAR | PASS | 5/13/2020 | BING COSBY |
322 DIAPRAGM SHEAR | PASS | 5/15/2020 | BING COSBY |
SHOWER PAN | PASS | 5/18/2020 | BING COSBY |
323 DIAPRAGM ROOF | NOT READY | 5/22/2020 | CHRIS BABCOCK |
322 DIAPRAGM SHEAR | PASS | 5/26/2020 | BING COSBY |
350 FRAMING | PASS | 5/26/2020 | BING COSBY |
525 ELECT ROUGH | NOT READY | 5/26/2020 | BING COSBY |
425 PLUMB ROUGH | PASS | 5/26/2020 | BING COSBY |
730 LATH | NOT READY | 5/26/2020 | BING COSBY |
455 MECHANICAL ROUGH | NOT READY | 5/26/2020 | BING COSBY |
425 PLUMB ROUGH | NO INSPECTION | 6/1/2020 | BING COSBY |
425 PLUMB ROUGH | PASS | 6/2/2020 | BING COSBY |
315 FRAME | NOT READY | 6/2/2020 | BING COSBY |
530 ELECT ROUGH | FAILED | 6/2/2020 | BING COSBY |
455 MECHANICAL ROUGH | PASS | 6/2/2020 | BING COSBY |
425 PLUMB ROUGH | | | |
425 PLUMB ROUGH | PASS | 6/5/2020 | BING COSBY |
525 ELECT ROUGH | PASS | 6/5/2020 | BING COSBY |
350 FRAMING | PASS | 6/5/2020 | BING COSBY |
455 MECHANICAL ROUGH | PASS | 6/5/2020 | BING COSBY |
SHOWER PAN | PASS | 6/9/2020 | BING COSBY |
550 METER RELEASE | | | |
605 INSULATION | PASS | 6/15/2020 | BING COSBY |
455 MECHANICAL ROUGH | PASS | 6/15/2020 | BING COSBY |
485 GAS TEST | PARTIAL | 6/15/2020 | BING COSBY |
525 ELECT ROUGH | PARTIAL | 6/15/2020 | BING COSBY |
705 WALL BOARD | PASS | 6/15/2020 | BING COSBY |
705 WALL BOARD | PASS | 6/19/2020 | BING COSBY |
705 WALL BOARD | PASS | 6/23/2020 | BING COSBY |
730 LATH | NOT READY | 6/23/2020 | BING COSBY |
550 METER RELEASE | NOT READY | 6/23/2020 | BING COSBY |
730 LATH | | | |
705 WALL BOARD | | | |
**920E FINAL | NO INSPECTION | 7/10/2020 | BING COSBY |
**905 FINAL SFR | NOT READY | 8/18/2020 | BING COSBY |
**905 FINAL SFR | PASS | 9/4/2020 | BING COSBY |
620 INSULATION | PASS | 6/10/2020 | BING COSBY |
705 WALL BOARD | PASS | 6/10/2020 | BING COSBY |
SHOWER PAN | PASS | 6/10/2020 | BING COSBY |
|
|
Fees:
|
FIRE SFD/DUPLEX PLAN CHECK | $606.27 | 1215315 | 09/18/2019 |
SFD/DUPLEX MODEL PLAN CHECK | $3,031.35 | 1215315 | 09/18/2019 |
WTR PLAN CHECK SFD/DUP | $454.70 | 1215315 | 09/18/2019 |
PLN-REVIEW OF BUILDING PERMIT | $158.00 | 1215315 | 09/18/2019 |
PUBLIC FACILITY RESIDENTIAL | $5,242.00 | 1351635 | 03/10/2020 |
PARK - RESIDENTIAL ONLY | $8,862.00 | 1351635 | 03/10/2020 |
RESUBMITTAL | $222.00 | 1351635 | 03/10/2020 |
BLD-BUILDING OFFICIAL REVIEW | $164.05 | 1346155 | 03/04/2020 |
FIRE SFD/DUPLEX INSPECT | $946.59 | 1351635 | 03/10/2020 |
GENERAL PLAN SURCHARGE | $473.30 | 1351635 | 03/10/2020 |
PERMIT IMAGING SURCHARGE | $5.00 | 1351635 | 03/10/2020 |
PERMIT TECHNOLOGY SURCHARGE | $94.66 | 1351635 | 03/10/2020 |
PLAN IMAGING SURCHARGE | $69.00 | 1351635 | 03/10/2020 |
RESIDENTIAL SMIP | $195.00 | 1351635 | 03/10/2020 |
SB 1473 GREEN TAX | $54.00 | 1351635 | 03/10/2020 |
SFD/DUPLEX MODEL PERMIT | $4,732.96 | 1351635 | 03/10/2020 |
HOURLY PLAN REVIEW FEE | $213.79 | 1429369 | 07/02/2020 |
HOURLY PLAN REVIEW FEE | $320.69 | 1485673 | 09/18/2020 |
ENG- FEMA ELEVATION CERTIFCATE | $255.00 | 1351635 | 03/10/2020 |
TEMP CERT OF OCCUPANCY | $399.85 | 1465162 | 08/20/2020 |
TEMP CERT OF OCCUPANCY | $31.84 | 1465162 | 08/20/2020 |
|
|
|
TOTAL FEES:
|
$26,532.05
|
TOTAL FEES PAID:
|
$26,532.05
|
TOTAL FEES DUE:
|
$0.00
|
|
|
|